CHECKING/REPLACING TEMPERATURE TIME SWITCH The temperature time switch controls the opening of the cold start valve while starting depending on the coolant temperature. The open time (max. 8 sec.) and switching off temperature (+ 35°C/95°F) are stamped on a hexagon. Unscrew temperature time switch. Installation: Check seal, replacing if necessary. Tightening torque¹). Fill and bleed cooling system 17 00 039. 17 00 039 ¹) See Specifications | |
Pull off wire plugs. Connect Jetronic test lead 61 1 440 on temperature time switch. Check resistance between red term. (W) and black term. (G), red term. (W) and ground as well as black term. (G) and ground with an ohmmeter. | |
Vehicles after change point in 1982 REMOVING AND INSTALLING/CHECKING TEMPERATURE TIME SWITCH The temperature time switch regulates the open time of the cold start valve, depending on the coolant temperature. The open time (e.g. 8 sec.) and switching-off temperature (e.g. +35°C/ 95°F) are stamped on the hexagon. | |
Removing and Installing: Pull off plug (1). Unscrew temperature time switch. Installation: Tightening torque*. * See Specifications | |
Installation: Check code number (1)*. Replace seal (2). FD = Manufacturing date Fill and bleed cooling system (Grouß 17). * See Specifications | |
Checking: Connect Jetronic test lead 61 1 440. Check nominal value* with ohmmeter. To check the entire temperature range, remove and place temperature sensor in a water bath heated to testing temperature. Check resistance* with an ohmmeter. * See Specifications |