Vehicles after change point in 1982 REMOVING AND INSTALLING/CHECKING TEMPERATURE TIMW SWITCH The temperature time switch regulates the open time of the cold start valve in accordance with the coolant temperature. The open time (e.g. 8 seconds) and switching off temperature (e.g. +35°C = 95°F) are stamped on the hexagon. | |
Removing and Installing: Pull off plug (1). Unscrew temperature time switch. Installation: Tightening torque*. * See Specifications | |
Installation: Check code number (1)*. Replace seal (2). FD = Manufacturing date Fill and bleed cooling system - see Group 17. * See Specifications | |
Testing: Connect Jetronic test leads 61 1 440. Check nominal value* with an ohmmeter. Testing Entire Temperature Range: Remove temperature sensor, heat to testing temperature in a water bath and check resistance* with an ohmmeter. * See Specifications |