Vehicles after change point in 1982 CHECKING OPERATION OF POWER STEERING (H-31 SYSTEM) - Engine At Operating Temperature - Check hydraulic fluid level in tank. Check all hose connections and equipment (pump, brake booster, power flow regulator and steering gear) for leaks before checking operation. | |
Discharging Pressure: Operate brake pedal about 20 times with engine stopped. Install pressure tester 32 4 000 between pump and power flow regulator. 1 = Power flow regulator or steering gear connection 2 = Pump connection | |
A = Shutoff valve (low pressure: 0 to 15 bar or 0 to 213 psi) Caution! Shutoff valve (A) must always be closed for high pressure tests to avoid damaging pressure tester. B = Shutoff valve (high pressure: 0 to 150 bar or 0 to 2133 bar) Open valve (B). Close valve (A). Start engine - fill hydraulic fluid** in tank. Bleeding System: Turn steering wheel two times each against left and right locks. Operate brake pedal 5 times, wait 30 seconds and operate pedal another 5 times. Hydraulic fluid temperature should be approx. 50°C (122°F) for all tests. Turning steering wheel against locks with engine running could cause a rise in temperature. ** See Service Information of Gr. 00 | |
1. Checking Flow Pressure: Open valve (B). Close valve (A) and run engine. Open valve (A) and read pressure when pressure is less than 15 bar (213 psi). Max. permissible flow pressure of 8 bar (114 psi) must not be exceeded. Pressure Greater Than 8 Bar (114 psi): |