REPLACING POINTS
Remove distributor cap.
Remove rotor, dust cap and point protection cap.
Disconnect flat male plug (1).
Unscrew screw (2).
Pull out contact breaker points.
Installation: Clean new points to remove grease.
Soak felt pad (3) in engine oil.
Lubricate cam and bearing prart (4) on contact
breaker anvil with Bosch Ft 1 v 4 grease.
Adjust dwell angle and ignition timing 12 11 004.


Siehe auch 12 11 004