Vehicles after change point in 1982
REMOVING AND INSTALLING
OR REPLACING EXPANSION
VALVE
Remove evaporator housing 64 51 020.
Remove clamps (seven).
Unscrew bolt (1).
Cut off plastic rivet.


Siehe auch 64 51 020
2864042 - click to zoom
 
Remove upper housing section with blower motor.
Pull evaporator out of housing.
Unscrew bolts (1 ... 3).
Insert plugs in open line connections immediately.
Remove insulating compound and disconnect clamp (4).
Installation:
Secure coil (5) on pipe with clamp (4) and protect against ambient temperature
with insulating compound.

2864045 - click to zoom