Turn on ignition and check operation. Switch Positions: 1 = Left outside mirror 2 = Right outside mirror Adjusting Mirror: 3/4 Vertical plane 5/6 Horizontal plane DESCRIPTION The outside mirror can be adjusted and heated after turning on the ignition. Heating is controlled automatically. Heating is switched on by an integrated temperature switch when the mirror glass temperatur is below +15 ± 5°C (59 ± 9°F). Heating is switched off automatically when a temperature of 50 ± 10°C (122 ± 18°F) is reached. Heating switches is again when the temperature would drop below +15 ± 5°C (59 ± 9°F). The melting speed at -10°C (+14°F) for a frozen mirror is about 5 minutes with a power consumption of approx. 1.5 A.
|