Vehicles after change point in 1982 Unscrew shield.
Unscrew screws of spped and reference mark sensors (D an B) and pull out sensors. Installation: Mark new reference mark sensor (B) with a piece of tape.
Pull off plugs on speed sensor (D) and reference mark sensor (B). Press plug of sensor lead out of holder. Installation: Plug marked with tape belongs to gray plug.
Pull of protective sleeve (1). Lift out clip (2). Installation. Coat seals with Molykote paste. Keep grease and dirt off of face surface on sensors.
Testing: Disconnect plug. Connect BMW service test unit to operating instructions (M 06/22/23). Use universal test leads. B = Reference mark sensor D = Speed sensor